Standards such as OSHA, EH40 and TUV in Europe mandate that employees and members of the public are not exposed to potentially dangerous levels of CO2 as it is a highly toxic gas in relatively small quantities.
Guidelines also advise consideration be given to the use of oxygen monitors where inert gases such as nitrogen are used, as a leak can cause an asphyxiation risk.
The NHS SOPS (Standard Operating Procedures) also details the requirement for oxygen (O2) enrichment monitoring.
ASPIDA
Operating temperature | -5°C to +50°C |
Humidity Range | 0 to 99% RH |
Display | High-visibility, Organic Light Emitting Diode (OLED) display |
Alarm horn | 95dB @ 30cm (110dB - man-down alarm) |
LED indicators | 1 x Green - OK, 1 x Amber - Fault, 1 x Red - Alarm |
Internal data log | 1 log every 30 seconds for at least 7 days of continuous use |
Batteries | 2 x NiMH 2100mAh AA batteries (or suitable AA type batteries) |
Battery discharge time | 15 hours under normal operation (passive atmospheric monitoring, minimal user interaction, no alarms) |
Battery lifespan | 2 years |
Battery charge time | 4.5 hours (from flat) |
Charge power supply rating | 9 V DC - 0.55A |
Dimensions | 127 x 44 x 90 mm / 5 x 1.7 x 3.5 inches (HxDxW) |
Electronics warranty | 2 years |
IP rating | IP65 |
ASPIDA SENSORS
CO2 Sensor | O2 Sensor | |
---|---|---|
Sensor type | Analox infrared MIR | Electrochemical |
Range | 0.01 to 5% | 0.1 to 25% |
Accuracy (at standard temperature and pressure) | ±2% of full scale between 0.01% and 2.5%, ±3% | ±3% of full scale between 0.1% and 25% |
Response time | T90 <60 seconds | T90 <30 seconds |
Sensor life span | 5 years | 2 year (expected) |
Enriched oxygen (O2) can cause a condition on the human body called hyperoxia, enriched CO2 is highly toxic, both are a threat to life and must be safeguarded against.
If an inert gas such as nitrogen (N2), argon (Ar), helium (He) or liquid nitrogen (LN2) leaks then this will deplete the levels of oxygen (O2) in the surrounding area, creating a dangerous atmosphere.
The Aspida can offer personal protection and alerts to all of these risks, offering you true peace of mind.
Offering audible and visual alarms, data logging and a man down alarm for lone workers, it is an ideal solution to protect staff from the dangers of a leak of carbon dioxide (CO2), oxygen (O2) or inert gas.
The Aspida is an affordable, easy to operate gas detection monitor and is perfect for ensuring safety in areas where the gas is piped, used or stored.
It operates using rechargeable battery technology allowing it to run for more than 12 hours continuously between charges.